{"id":6631,"date":"2026-11-08T09:09:14","date_gmt":"2026-11-08T06:09:14","guid":{"rendered":"https:\/\/www.arktrade.com.tr\/en\/konica-minolta-printhead-cleaning\/"},"modified":"2026-11-08T09:29:25","modified_gmt":"2026-11-08T06:29:25","slug":"konica-minolta-printhead-cleaning","status":"publish","type":"page","link":"https:\/\/www.arktrade.com.tr\/en\/konica-minolta-printhead-cleaning\/","title":{"rendered":"Konica Minolta Printhead Cleaning and Testing: KM1024i, KM1024, KM1800i"},"content":{"rendered":"<div class=\"wpb-content-wrapper\" id=\"wpb-content-root\"><p>[vc_row content_width=&#8221;grid&#8221;][vc_column][vc_column_text]<\/p>\n<div class=\"ark-lead\">\n<p>The Konica Minolta KM1024i and KM1024 series are widely used, from solvent and UV wide-format printing to textile and industrial applications. In the head code, S, M and L indicate drop size, while H and N indicate heated or non-heated versions; the cleaning recipe is chosen according to these features and the ink used.<\/p>\n<\/div>\n<div class=\"ark-sec-head\">\n<h2>Supported Konica Minolta printheads<\/h2>\n<p>Main Konica Minolta models that can be processed with Cleanjector and Inktester Digital:<\/p>\n<\/div>\n<div class=\"ark-models\">\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Nozzles<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>KM1024i SHE<\/strong><\/td>\n<td>1024 (256\u00d74)<\/td>\n<\/tr>\n<tr>\n<td><strong>KM1024i MHE-D<\/strong><\/td>\n<td>1024 (256\u00d74)<\/td>\n<\/tr>\n<tr>\n<td><strong>KM1024i LHE-30<\/strong><\/td>\n<td>1024 (256\u00d74)<\/td>\n<\/tr>\n<tr>\n<td><strong>KM1024i SAE-C<\/strong><\/td>\n<td>1024 (256\u00d74)<\/td>\n<\/tr>\n<tr>\n<td><strong>KM1024i MAE-C<\/strong><\/td>\n<td>1024 (256\u00d74)<\/td>\n<\/tr>\n<tr>\n<td><strong>KM1024 SHB \/ MHB \/ LHB<\/strong><\/td>\n<td>1024 (512\u00d72)<\/td>\n<\/tr>\n<tr>\n<td><strong>KM1024 MNB \/ LNB<\/strong><\/td>\n<td>1024 (512\u00d72)<\/td>\n<\/tr>\n<tr>\n<td><strong>KM1800i SHC-C<\/strong><\/td>\n<td>1776 (296\u00d76)<\/td>\n<\/tr>\n<tr>\n<td><strong>KM1024A LHG-RC<\/strong><\/td>\n<td>1024<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"ark-note\">Other supported models: KM512i LNB, KM512i MAB, KM512i SAE-Q, KM1024A SAE-Q, KM1024A SHE-HR.<\/p>\n<p class=\"ark-note\">Technical data from the head manufacturer and People &amp; Technology; the model list may change as it is updated.<\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row content_width=&#8221;grid&#8221;][vc_column][vc_column_text]<\/p>\n<div class=\"ark-sec-head\">\n<h2>Common problems with Konica Minolta heads<\/h2>\n<\/div>\n<div class=\"ark-areas\">\n<div class=\"ark-area\"><i class=\"fa fa-ellipsis-h\"><\/i><\/p>\n<h4>Missing nozzles and lines<\/h4>\n<p>Dried or settled ink blocks nozzles, causing lines, colour shifts and missing patterns.<\/p>\n<ul class=\"ark-ul\">\n<li>Gaps in the nozzle test<\/li>\n<li>Jet deviation<\/li>\n<li>Reduced drop volume<\/li>\n<\/ul>\n<\/div>\n<div class=\"ark-area\"><i class=\"fa fa-exchange\"><\/i><\/p>\n<h4>Ink changeover<\/h4>\n<p>When switching to another ink or supplier, residues of the old ink may be incompatible with the new one.<\/p>\n<ul class=\"ark-ul\">\n<li>Controlled flushing<\/li>\n<li>Compatible cleaning fluid<\/li>\n<li>Testing after changeover<\/li>\n<\/ul>\n<\/div>\n<div class=\"ark-area\"><i class=\"fa fa-pause-circle\"><\/i><\/p>\n<h4>Long stoppages<\/h4>\n<p>Ink drying and pigment settling in the head during maintenance and downtime.<\/p>\n<ul class=\"ark-ul\">\n<li>Pre-flushing and protection<\/li>\n<li>Safe storage<\/li>\n<li>Priming before restart<\/li>\n<\/ul>\n<\/div>\n<div class=\"ark-area\"><i class=\"fa fa-exclamation-triangle\"><\/i><\/p>\n<h4>Incorrect cleaning<\/h4>\n<p>Pressure above the manufacturer\u2019s limits, unsuitable solvents or cleaning under power can cause permanent damage.<\/p>\n<ul class=\"ark-ul\">\n<li>Model-specific recipe<\/li>\n<li>No power to the head<\/li>\n<li>Pressure and vacuum control<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row content_width=&#8221;grid&#8221;][vc_column][vc_column_text]<\/p>\n<div class=\"ark-stage\">\n<div class=\"ark-stage-img\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/10\/cleanjector-1.jpg\" alt=\"Konica Minolta printhead cleaning Cleanjector\" loading=\"lazy\" \/><\/div>\n<div class=\"ark-stage-txt\"><span class=\"ark-kicker\">People &amp; Technology<\/span><\/p>\n<h3>Cleaning Konica Minolta heads with Cleanjector<\/h3>\n<p>Cleanjector controls pressure, vacuum, flow direction, temperature, time and ultrasound according to the Konica Minolta head model. Cleaning is carried out with closed-loop filtration and backflush; no power is applied to the head during cleaning.<\/p>\n<ul class=\"ark-ul\">\n<li>Recipes and adapters specific to Konica Minolta models<\/li>\n<li>Oil, solvent, water-based and UV inks<\/li>\n<li>Up to 93% recovery of heads in suitable condition with ceramic inks<\/li>\n<\/ul>\n<p class=\"ark-chips\"><a class=\"ark-chip\" href=\"\/en\/printhead-cleaning\/\">Printhead cleaning<\/a> <a class=\"ark-chip\" href=\"\/en\/solution-partners\/people-technology\/\">People &amp; Technology<\/a><\/p>\n<\/div>\n<\/div>\n<div class=\"ark-stage\">\n<div class=\"ark-stage-img\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/10\/banner-inktester.jpg\" alt=\"Konica Minolta printhead testing Inktester Digital\" loading=\"lazy\" \/><\/div>\n<div class=\"ark-stage-txt\"><span class=\"ark-kicker\">People &amp; Technology<\/span><\/p>\n<h3>Measurable results with Inktester Digital<\/h3>\n<p>Whether a cleaned Konica Minolta head is ready to return to the line is tested in the lab without stopping production. The same platform is used for new ink approval and incoming head inspection.<\/p>\n<ul class=\"ark-ul\">\n<li>Nozzle, drop and waveform checks<\/li>\n<li>Before \/ after cleaning comparison<\/li>\n<li>Head lifetime tracking<\/li>\n<\/ul>\n<p class=\"ark-chips\"><a class=\"ark-chip\" href=\"\/en\/solution-partners\/people-technology\/\">People &amp; Technology<\/a><\/p>\n<\/div>\n<\/div>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row content_width=&#8221;grid&#8221;][vc_column][vc_column_text]<\/p>\n<h2 class=\"ark-faq-h\">Frequently asked questions<\/h2>\n<div class=\"ark-faq\">\n<details class=\"ark-faq-item\">\n<summary>\n<h3>Can a clogged Konica Minolta printhead be cleaned?<\/h3>\n<\/summary>\n<div class=\"ark-faq-a\">\n<p>A significant share of Konica Minolta heads without electrical or mechanical damage can be returned to production through controlled cleaning with a model-specific recipe. The head condition is verified by testing before and after cleaning.<\/p>\n<\/div>\n<\/details>\n<details class=\"ark-faq-item\">\n<summary>\n<h3>What should be considered when cleaning Konica Minolta heads?<\/h3>\n<\/summary>\n<div class=\"ark-faq-a\">\n<p>The manufacturer\u2019s pressure and temperature limits must not be exceeded, a cleaning fluid compatible with the ink must be used and no power must be applied to the head during cleaning. Cleanjector controls these parameters automatically according to the head model.<\/p>\n<\/div>\n<\/details>\n<details class=\"ark-faq-item\">\n<summary>\n<h3>How do you know a cleaned Konica Minolta head is sound?<\/h3>\n<\/summary>\n<div class=\"ark-faq-a\">\n<p>Inktester Digital checks nozzle condition, drop formation and waveform; comparing results before and after cleaning shows objectively whether the head is ready to return to the line.<\/p>\n<\/div>\n<\/details>\n<details class=\"ark-faq-item\">\n<summary>\n<h3>Heads running which inks can be cleaned?<\/h3>\n<\/summary>\n<div class=\"ark-faq-a\">\n<p>Recipes are available for heads running oil-based (including ceramic), solvent-based, water-based and UV inks. The cleaning fluid is selected according to the ink used.<\/p>\n<\/div>\n<\/details>\n<details class=\"ark-faq-item\">\n<summary>\n<h3>When does a printhead cleaning system pay back?<\/h3>\n<\/summary>\n<div class=\"ark-faq-a\">\n<p>Payback depends on annual head consumption and the number of heads recovered; in high-consumption plants it drops to around 6\u20138 months. We calculate it with your head consumption data.<\/p>\n<\/div>\n<\/details>\n<\/div>\n<p><script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Can a clogged Konica Minolta printhead be cleaned?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"A significant share of Konica Minolta heads without electrical or mechanical damage can be returned to production through controlled cleaning with a model-specific recipe. The head condition is verified by testing before and after cleaning.\"}}, {\"@type\": \"Question\", \"name\": \"What should be considered when cleaning Konica Minolta heads?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The manufacturer\u2019s pressure and temperature limits must not be exceeded, a cleaning fluid compatible with the ink must be used and no power must be applied to the head during cleaning. Cleanjector controls these parameters automatically according to the head model.\"}}, {\"@type\": \"Question\", \"name\": \"How do you know a cleaned Konica Minolta head is sound?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Inktester Digital checks nozzle condition, drop formation and waveform; comparing results before and after cleaning shows objectively whether the head is ready to return to the line.\"}}, {\"@type\": \"Question\", \"name\": \"Heads running which inks can be cleaned?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Recipes are available for heads running oil-based (including ceramic), solvent-based, water-based and UV inks. The cleaning fluid is selected according to the ink used.\"}}, {\"@type\": \"Question\", \"name\": \"When does a printhead cleaning system pay back?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Payback depends on annual head consumption and the number of heads recovered; in high-consumption plants it drops to around 6\u20138 months. We calculate it with your head consumption data.\"}}]}<\/script><\/p>\n<p class=\"ark-related\">Other printhead brands: <a href=\"\/en\/seiko-printhead-cleaning\/\">Seiko<\/a> \u00b7 <a href=\"\/en\/kyocera-printhead-cleaning\/\">Kyocera<\/a> \u00b7 <a href=\"\/en\/xaar-printhead-cleaning\/\">Xaar<\/a> \u00b7 <a href=\"\/en\/dimatix-starfire-printhead-cleaning\/\">Fujifilm Dimatix<\/a> \u00b7 <a href=\"\/en\/ricoh-printhead-cleaning\/\">Ricoh<\/a> \u00b7 <a href=\"\/en\/epson-i3200-printhead-cleaning\/\">Epson<\/a> \u00b7 <a href=\"\/en\/toshiba-printhead-cleaning\/\">Toshiba<\/a> \u00b7 <a href=\"\/en\/printhead-cleaning\/\">All printhead cleaning solutions<\/a><\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<div class=\"ark-cta\">\n<div class=\"ark-cta-in\">\n<h2>Let\u2019s plan cleaning and testing for your Konica Minolta heads<\/h2>\n<p>Share your head model, ink type and annual head consumption; we will evaluate the right solution and payback together.<\/p>\n<p class=\"ark-btns\"><a class=\"ark-btn\" href=\"\/en\/contact\/\">Contact us<\/a> <a class=\"ark-btn ark-btn-ghost\" href=\"\/en\/solution-partners\/people-technology\/\">People &amp; Technology<\/a><\/p>\n<\/div>\n<\/div>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row content_width=&#8221;grid&#8221;][vc_column][vc_column_text]<\/p>\n<p class=\"ark-foot\"><a class=\"ark-link\" href=\"\/en\/printhead-cleaning\/\">\u2190 Printhead cleaning<\/a> <a class=\"ark-link\" href=\"\/en\/solution-partners\/people-technology\/\">About People &amp; Technology \u2192<\/a><\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Cleaning of Konica Minolta KM1024i SHE, MHE, LHE, SAE, MAE, KM1024 SHB, MHB, LHB, KM1800i and KM512i printheads with Cleanjector, and testing with Inktester Digital.<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"full-width.php","meta":{"_monsterinsights_skip_tracking":false,"footnotes":""},"class_list":["post-6631","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.arktrade.com.tr\/en\/wp-json\/wp\/v2\/pages\/6631","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.arktrade.com.tr\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.arktrade.com.tr\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.arktrade.com.tr\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.arktrade.com.tr\/en\/wp-json\/wp\/v2\/comments?post=6631"}],"version-history":[{"count":2,"href":"https:\/\/www.arktrade.com.tr\/en\/wp-json\/wp\/v2\/pages\/6631\/revisions"}],"predecessor-version":[{"id":6651,"href":"https:\/\/www.arktrade.com.tr\/en\/wp-json\/wp\/v2\/pages\/6631\/revisions\/6651"}],"wp:attachment":[{"href":"https:\/\/www.arktrade.com.tr\/en\/wp-json\/wp\/v2\/media?parent=6631"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}